Erdington Leisure (July 2003)

Location: Leisure Complex, Erdington, West Midlands

Building construction
External walls were constructed using standard PUR insulated horizontal wall panels (picture 1) The storeroom in which the fire occurred was located adjacent to external wall and was constructed with block work walls to 2.5 metres high with a false ceiling.

Picture 1.

Fire
The fire took place in the storeroom. The storeroom contained a high fire load and the intensity of the fire is indicated by the damage to the fire resisting wooden door frame (picture 2).

Picture 2.

The fire broke out of the storeroom resulting in direct flame impingement on the adjacent panels.

Observations
Charring was visible at the joints where there had been direct impingement (picture 3).
Although the metal purlins above the seat of the fire were distorted, the panel joints did not open up and there was no evidence of ignition or fire spread.
 
Picture 3.

 

Back to top. Also in this section:
Fire performance of insulated panels  |  Guide to fire safety  |  Fire tests  |
Findings of fire research on major fires